Monday, February 7, 2011

TESTING - FRESH CONCRETE

The suitability of a concrete for any task is initially assessed whilst that concrete is still in its freshly mixed state before setting occurs:
  • Is it workable?
  • Will it pump
  • Does it hold together or segregate?
  • Is it air entrained?
  • Will it bleed?
Well established tests are used to categorize fresh concrete properties.

Workability/Consistency

  • Slump test - the most widely used test for assessing the workability of concrete of normal consistency (slump 10mm to 200mm).
  • Flow Table test - for concretes that are more free flowing (slump 180mm+).
  • Vebe Test - for concretes that are not workable in the normal sense, the test uses integral vibration.
Control and measurement of air content is easily assessed using a pressure type air meter.
Fresh density, compactability and bleeding can all be measured.
From Quality Control and Mix Design assessment to Admixture testing.

References : BS EN 12350 series, Testing fresh concrete


SLUMP TEST







FLOW TEST











2 comments:

  1. your all article are excellent and useful specially this one...

    ReplyDelete
  2. http://www.setestindia.com/concrete-flow-table-test.html

    ReplyDelete